<pre> | |||
~# smartctl --capabilities /dev/sda | |||
smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) | |||
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net | |||
=== START OF READ SMART DATA SECTION === | |||
General SMART Values: | |||
Offline data collection status: (0x82) Offline data collection activity | |||
was completed without error. | |||
Auto Offline Data Collection: Enabled. | |||
Self-test execution status: ( 244) Self-test routine in progress... | |||
40% of test remaining. | |||
Total time to complete Offline | |||
data collection: ( 600) seconds. | |||
Offline data collection | |||
capabilities: (0x7b) SMART execute Offline immediate. | |||
Auto Offline data collection on/off support. | |||
Suspend Offline collection upon new | |||
command. | |||
Offline surface scan supported. | |||
Self-test supported. | |||
Conveyance Self-test supported. | |||
Selective Self-test supported. | |||
SMART capabilities: (0x0003) Saves SMART data before entering | |||
power-saving mode. | |||
Supports SMART auto save timer. | |||
Error logging capability: (0x01) Error logging supported. | |||
General Purpose Logging supported. | |||
Short self-test routine | |||
recommended polling time: ( 1) minutes. | |||
Extended self-test routine | |||
recommended polling time: ( 84) minutes. | |||
Conveyance self-test routine | |||
recommended polling time: ( 2) minutes. | |||
SCT capabilities: (0x103f) SCT Status supported. | |||
SCT Error Recovery Control supported. | |||
SCT Feature Control supported. | |||
SCT Data Table supported. | |||
</pre> | |||
Ici, le disque supporte le short self-test (d'une durée d'environs 1 minute), l'extended self-test (d'une durée d'environs 84 minutes) et le Conveyance self-test (d'une durée d'environs 2 minutes). | |||